{"id":3523,"date":"2020-06-13T11:35:27","date_gmt":"2020-06-13T11:35:27","guid":{"rendered":"https:\/\/wiki.itripcomputer.com\/?page_id=3523"},"modified":"2025-09-06T09:33:33","modified_gmt":"2025-09-06T09:33:33","slug":"calibration","status":"publish","type":"page","link":"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/","title":{"rendered":"|H-51| Calibration"},"content":{"rendered":"\n<p class=\"has-ast-global-color-5-color has-vivid-cyan-blue-background-color has-text-color has-background has-link-color has-small-font-size wp-elements-1 wp-block-paragraph\" style=\"font-style:normal;font-weight:500\">MENU Tipmeter iTripcomputer H-51<br\/><br\/><a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/\">Tripmeter H-51 <\/a>| <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/specification\/\">Specifications<\/a><br\/><a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/handling-basics\/\">Service &#8211; basics<\/a> | <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/h-51-service-during-the-rally\/\">Service during a rally<\/a><br\/><a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/h-51-connection\/\">Connection<\/a> | <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/h-51-configuration\/\">Configuration <\/a>| <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/\">Calibration <\/a>| <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/operating-modes\/\">Operating modes<\/a> | <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/h-51-azimuth-mode-operation\/\">Azimuth mode<\/a> operation.<br\/><a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/technical-and-operational-data\/\">Specifications<\/a> | <a href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/h-51-faq\/\">FAQ<\/a> | <a href=\"https:\/\/wiki.itripcomputer.com\/en\/h-51-movies\/\">Videos<\/a><\/p>\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Na tej stronie dowiesz si\u0119:<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #494949;color:#494949\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #494949;color:#494949\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#H-51_metrometer_calibration\" >H-51 metrometer calibration<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Calibration_according_to_known_distance\" >Calibration according to known distance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Calibration_value_measurement_function\" >Calibration value measurement function<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Calibration_value_entry_function\" >Calibration value entry function<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#GPS-based_auto-calibration_function\" >GPS-based auto-calibration function *<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Activation_of_calibration_factor_%E2%80%93_only_when_MULTIk_parameter_ON\" >Activation of calibration factor &#8211; only when MULTIk parameter = ON<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Checking_the_value_of_the_active_factor\" >Checking the value of the active factor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Calibration_menu_with_MULTIk_ON\" >Calibration menu with MULTIk = ON<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/wiki.itripcomputer.com\/en\/tripmeters\/tripmeter-h-51\/calibration\/#Vehicle_calibration_factor\" >Vehicle calibration factor<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 class=\"wp-block-heading\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"H-51_metrometer_calibration\"><\/span>H-51 metrometer calibration<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n<p class=\"wp-block-paragraph\">The manual describes all the methods for calibrating the distance measurement.<\/p>\n\n<h2 class=\"wp-block-heading\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Calibration_according_to_known_distance\"><\/span>Calibration according to known distance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">The simplest method of calibrating a tripmeter is to match the ODO distance display to the actual distance travelled of a known length. The length of the section can be any, the longer the section the more accurate the calibration, but the calibration section should not be longer than a few kilometres.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Press <strong>MENU long<\/strong> to bring the tripmeter to the start screen position.<br\/>When you see the start screen <strong>[ _ _ _ _ ]<\/strong> skip this point<\/li>\n\n\n\n<li>switch the tripmeter to the measurement position by pressing the <strong>F<\/strong> button ( ODO and TRIP will be equal to 0 )<\/li>\n\n\n\n<li>and then drive a road section of known length<\/li>\n\n\n\n<li>stop at the end of it<\/li>\n\n\n\n<li>press <strong>CAL briefly<\/strong> <strong>2 x,<\/strong> which causes the current calibration factor to flash<\/li>\n\n\n\n<li>press the <strong>arrow buttons<\/strong> and bring the ODO distance indication ( which will replace the calibration factor value on the display ) to the known distance you have travelled<\/li>\n\n\n\n<li>press <strong>F briefly<\/strong> to accept the change or leave it on the screen and after 6 seconds the change will be accepted.<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\">When the coefficient exceeds the value of <strong>9999<\/strong> the rightmost, least significant digit will disappear and all the dots between the digits will light up to signal such a situation. Pay attention because you will not be able to see the numbers that have slipped off the screen. <\/p>\n\n<h2 class=\"wp-block-heading\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Calibration_value_measurement_function\"><\/span>Calibration value measurement function<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">It is possible to measure calibration values on the H-51 tripmeter. You can measure over any distance, but enter the calibration value converted for a 1000m stretch of road into the tripmeter ( e.g. if you measure over 100m, multiply the measured value x10 and enter it into the tripmeter).<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Press <strong>MENU long<\/strong> to bring the tripmeter to the start screen position. <br\/>When you see the start screen <strong>[ _ _ _ _ ] <\/strong>skip this point.<\/li>\n\n\n\n<li>Press <strong>the MENU button briefly<\/strong> until <strong>POM<\/strong> is shown, then press the <strong>F button<\/strong>. The appearance of the digit <strong>0<\/strong> when the tripmeter is not counting pulses or the counting screen when the tripmeter is counting pulses confirms the activation of the function<\/li>\n\n\n\n<li>press button <strong>F<\/strong> to delete the measured value and start the measurement again ( e.g. at the beginning of a calibration section ) <\/li>\n\n\n\n<li>press <strong>the up arrow button<\/strong> to stop measuring, then press <strong>the up arrow button<\/strong> again to resume measuring<\/li>\n\n\n\n<li>Press <strong>the F button for a long<\/strong> time to save the measurement.<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\">When measuring a factor of more than 4 digits , as soon as the measurement exceeds 9999 the last right least significant digit will disappear and all the dots between the digits will light up to indicate such a situation. Pay attention because you will not be able to see the numbers that have slipped off the screen. Also consider measuring the calibration factor over a distance of less than 1,000 m.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"H-51-funkcja-wpisywania-wartosci-kalibracji\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Calibration_value_entry_function\"><\/span>Calibration value entry function<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">It is possible to enter a known calibration value in the tripmeter. When you set the <strong>MULTI k<\/strong> parameter to <strong>OFF<\/strong>, you can enter <strong>1 calibration factor,<\/strong> and when you set the <strong>MULTI k<\/strong> parameter to <strong>ON,<\/strong> you can enter up to <strong>10 factors by assigning<\/strong> consecutive numbers to them.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Press <strong>MENU for a long<\/strong> time to bring the tripmeter to the start screen position. <\/li>\n\n\n\n<li>When you see the start screen <strong>[ _ _ _ ]<\/strong> skip this point<\/li>\n\n\n\n<li>press the <strong>MENU button briefly<\/strong> until <strong>WPIS<\/strong> is shown, then press the <strong>F button<\/strong>. When theu <strong>_<\/strong> sign appears, it confirms that the function has been started.<\/li>\n\n\n\n<li>enter the calibration value using the buttons:<ul><li><strong>the up\/down arrow briefly<\/strong> changes the value of the digit,<\/li><\/ul><\/li>\n\n\n\n<li><ul><li><strong>F briefly,<\/strong> which moves a digit to the left and allows you to enter the next digit<\/li><\/ul>\n<ul class=\"wp-block-list\">\n<li><strong>MENU briefly<\/strong> deletes the last digit (by pressing the menu you can stop typing altogether)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>press button <strong>F long<\/strong> to save the entered coefficient<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\"><strong>NOTE:<\/strong> When <strong>Multi k<\/strong> is enabled after storing a value, you will see a screen designed for entering the calibration memory number under which you will store the measured value. <br\/><br\/>When you enter a factor of more than 4 digits , as soon as the first digit on the left is out of the screen, all the dots between the digits light up to indicate such a situation. Pay attention because you will not be able to see the numbers that have slipped off the screen.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"H-51-funkcja-auto-kalibracji-z-wykorzystaniem-systemu-GPS\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"GPS-based_auto-calibration_function\"><\/span>GPS-based auto-calibration function *<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">The H-51 tripmeter is capable of auto calibration using GPS. Calibration can replace the calibration section.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Press <strong>MENU long<\/strong> to bring the tripmeter to the start screen position. <br\/>When you see the start screen <strong>[ _ _ _ _ ] <\/strong>skip this point.<\/li>\n\n\n\n<li>press the <strong>MENU button briefly<\/strong> until <strong>AUTO<\/strong> is displayed, then press the <strong>F button<\/strong><\/li>\n\n\n\n<li>When you see the word <strong>AUTO<\/strong> flashing, start the calibration . The measurement will start when the vehicle speed is greater than 15 km\/h and the number of satellites is greater than 6.<\/li>\n\n\n\n<li>press <strong>F briefly<\/strong> to interrupt and restart the self-calibration at any time<\/li>\n\n\n\n<li>drive until the counting stops, which will mean driving 1000 m and the end of auto-calibration<\/li>\n\n\n\n<li>Press the <strong>F button for a long<\/strong> time to save the measured coefficient.<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\">If you slow down or the GPS signal weakens during the measurement, the auto-calibration is interrupted and you will see the blinking <strong>AUTO<\/strong> text<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"H-51-aktywacja-wspolczynnika-kalibracyjnego-tylko-gdy-parametr-MULTIk=ON\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Activation_of_calibration_factor_%E2%80%93_only_when_MULTIk_parameter_ON\"><\/span>Activation of calibration factor &#8211; only when MULTIk parameter = ON<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">When using multiple calibration factors ( e.g. for different tyre sizes ) , a calibration factor must be selected from memory in order to be active. The selection of a coefficient is permanent &#8211; it will be used for calculations until another value is selected.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>during measurements press <strong>1x CAL briefly<\/strong> &#8211; you will see the active coefficient<\/li>\n\n\n\n<li>press <strong>the up or down arrow button<\/strong> to browse through the stored coefficients<\/li>\n\n\n\n<li>select coefficient<\/li>\n\n\n\n<li>press <strong>buttonF briefly<\/strong> or wait 6 seconds to save your selection<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\" id=\"H-51-sprawdzanie-wartosci-aktywnego-wspolczynnika\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Checking_the_value_of_the_active_factor\"><\/span>Checking the value of the active factor<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<ul class=\"wp-block-list\">\n<li>Press <strong>MENU long<\/strong> to bring the tripmeter to the start screen position. <br\/>When you see the start screen <strong>[ _ _ _ _ ] <\/strong>skip this point.<\/li>\n\n\n\n<li>switch off and then switch on the power supply to the tripmeter <\/li>\n\n\n\n<li>you will see the digits <strong>8888<\/strong> and then the active calibration factor will be displayed<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\">When the ratio contains more than 4 digits, the 4 most significant digits separated by dots will be shown. The 12000 factor will be presented as 1.2.0.0.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"H-51-menu-kalibracja-z-wlaczonym-parametrem-MULTIk=ON\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Calibration_menu_with_MULTIk_ON\"><\/span>Calibration menu with MULTIk = ON<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">When the <strong>MULTIk<\/strong> parameter is set to <strong>ON,<\/strong> when measuring, entering or auto-calibrating, you will have to enter the memory number under which you will store the coefficient after validating the measured value.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>perform the measurement, entry or auto-calibration according to the relevant chapters and confirm the measured\/entered value<\/li>\n\n\n\n<li>when you see <strong>[ _ ]<\/strong> after confirmation, press <strong>the up-arrow<\/strong> or <strong>down-arrow key<\/strong> to enter the memory number under which you will save the coefficient<\/li>\n\n\n\n<li><strong>press F<\/strong> to store the calibration value and memory number<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\"><strong>NOTE:<\/strong> Entering a calibration factor into memory does not automatically activate it.<\/p>\n\n<h2 class=\"wp-block-heading\" style=\"font-size:21px\"><span class=\"ez-toc-section\" id=\"Vehicle_calibration_factor\"><\/span>Vehicle calibration factor<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n<p class=\"wp-block-paragraph\">This is the number of road pulses counted from the vehicle corresponding to a journey of 1000 m. <br\/>Calibration factor you can:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>configure according to known distance [ recommended ]<\/strong><\/li>\n\n\n\n<li>measure a distance of any known length, but enter the number of pulses corresponding to a distance of 1000m into the tripmeter ( e.g. if you measured the number of pulses over a distance of 100m, multiply the measured value x10 and enter into the tripmeter)<\/li>\n\n\n\n<li>enter a known factor <\/li>\n\n\n\n<li>* measure by autocalibration using the built-in GPS module<\/li>\n<\/ul>\n\n<p class=\"has-ast-global-color-6-background-color has-background wp-block-paragraph\"><strong>[*] refers to the version with GPS<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>MENU Tipmeter iTripcomputer H-51 Tripmeter H-51 | SpecificationsService &#8211; basics | Service during a rallyConnection | Configuration | Calibration | Operating modes | Azimuth mode operation.Specifications | FAQ | Videos H-51 metrometer calibration The manual describes all the methods for calibrating the distance measurement. Calibration according to known distance The simplest method of calibrating a [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":3492,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[349,500],"tags":[],"class_list":["post-3523","page","type-page","status-publish","hentry","category-tripmeter-h-51-en","category-pages-in-english-en"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/wiki.itripcomputer.com\/en\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"MENU Tipmeter iTripcomputer H-51 Tripmeter H-51 | SpecificationsService &#8211; basics | Service during a rallyConnection | Configuration | Calibration | Operating modes | Azimuth mode operation.Specifications | FAQ | Videos H-51 metrometer calibration The manual describes all the methods for calibrating the distance measurement. Calibration according to known distance The simplest method of calibrating a&hellip;","_links":{"self":[{"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/pages\/3523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/comments?post=3523"}],"version-history":[{"count":27,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/pages\/3523\/revisions"}],"predecessor-version":[{"id":10531,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/pages\/3523\/revisions\/10531"}],"up":[{"embeddable":true,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/pages\/3492"}],"wp:attachment":[{"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/media?parent=3523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/categories?post=3523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wiki.itripcomputer.com\/en\/wp-json\/wp\/v2\/tags?post=3523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}